• Insertion flowmeter or batch controller with paddle wheel  and flow transmitter or remote batch controller Insertion flowmeter or batch controller with paddle wheel  and flow transmitter or remote batch controller
Insertion flowmeter or batch controller with paddle wheel  and flow transmitter or remote batch controller
Insertion flowmeter or batch controller with paddle wheel and flow transmitter or remote batch controller
Quantity

The form is no longer accepting responses. Try contacting the owner of the form if you think this is a mistake.

Description

Model: Insertion flowmeter or batch controller with paddle wheel

and flow transmitter or remote batch controller

 

  • Up to PN 10, measurement tube size DN 06 to DN 400
  • Display for showing the flow rate and volume with two totalisers, or

dosing

  • Automatic calibration via teach-in
  • Inputs (with batch controller) and all outputs can be checked without

the need for actual flow

  • Overall total and daily total for batch quantity and number of batches,

volume or mass totalisers displayed (with batch controller)

Performance data

Measurement deviation       • Teach-in: ± 1 % of the measured value at teach-in flow rate value

  • Standard K factor: ± 2.5 % of the measured value 

Linearity                     ± 0.5 % of full scale 

Repeatability                 ± 0.4 % of the measured value 

Electrical data

Power source (not supplied)        Limited power source according to UL/EN 62368-1 standards or limited energy circuit according to UL/

EN 61010-1 paragraph 9.4

DC reverse polarity protection            Yes

Overvoltage protection                  Yes

Voltage supply cable                  • Cable with maximum operating temperature greater than 80 °C (176 °F) (90 °C (194 °F) for UL-Recognized variant)

  • Max. 50 m length, shielded

Medium data

Fluid temperature                   With fitting Type S020 in:

  • PVC: 0…+ 50 °C (+ 32…+ 122 °F)
  • PP: 0…+ 80 °C (+ 32…+ 176 °F)
  • PVDF, stainless steel or brass: - 15…+ 80 °C (+ 5…+ 176 °F) (up to + 100 °C (212 °F) for flow meter with batteries)

Fluid pressure                       Max. PN 10

Viscosity                           Max. 300 cSt

Rate of solid particles                 Max. 1 %

Maximum particle size                  0.5 mm

Product connections

Process connection                    G 2" for use with Type S020 Insertion fitting

Approvals

Directives

Pressure equipment directive       Complying with article 4, paragraph 1 of 2014/68/EU directive

North America (USA/Canada)          UL Recognized for the USA and Canada

Environment and installation

Relative air humidity                   ≤ 80 %, without condensation

Height above sea level                  Max. 2000 m

Operating condition                    Continuous

Equipment mobility                     Fixed

Application range                      Indoor and outdoor

Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions.

Degree of protection according to IEC/EN 60529       IP65 with the following conditions met:

  • device wired
  • cover and lid screwed tight
  • female cable plug or glands mounted and tightened
  • with blind plug on unused cable glands

Installation category                            Category I according to UL/EN 61010-1

Pollution degree                               Degree 2 according to UL/EN 61010-1

Let's talk

Phone:+86 13505184827

Email:townsend@kunhui-valve.com

WhatsApp us